Good form, low roughness, and still not good enough
A European company develops grinding and finishing processes that bring large optics to optical surface quality. Its main concerns are surface texture and mid-spatial frequencies (MSF), and MSF are the harder of the two to isolate and control.
MSF sit between form and roughness: ripple, tool footprints and periodic structures that trace back to the grinding process, for example to the machine feed. Fine grinding and polishing make these structures smaller, but they remain on the surface. On the finished optic they show up as stray light, diffraction and loss of contrast. A mirror can meet its form specification, show excellent microroughness and still fail optically because of mid-frequency ripple. Two components with the same form and the same roughness can perform very differently.
For the company, MSF are a key quality criterion for its machines and processes, and they were not yet under control. To change that, the team first had to capture them reliably: over an area large enough for the longer spatial wavelengths, with enough lateral resolution to separate them from texture. The measurement setup used so far had reached its limits.

Long spatial wavelengths in one field, fine detail where needed
Before looking at instruments, the team defined what the measurement had to deliver. A single field had to be large enough to capture the longer spatial wavelengths, with enough lateral resolution to separate ripple from texture. Larger areas had to be stitched without degrading the result. The Z axis had to run reliably, finding the focus on polished surfaces should not slow the operator down, and measurements should run automatically.
Tests on a TopMap Micro.View+ showed how closely it matched this list. With a 0.6x objective, one field covers the longer spatial wavelengths and shows directly how ripple and tool marks are distributed across the surface. For larger areas, True Stitching joins neighboring fields, and at 0.6x only a few are needed. To find the focus on a polished optic, the operators use a higher-magnification objective with the Focus Finder, then switch to the 0.6x objective on the motorized turret. The same turret runs automated measurement sequences.
Mid-spatial frequencies become a process criterion
With form, MSF and texture captured on one instrument, the team can quantify the ripple their processes leave on the surface and compare it between parts and process variants. Two optics with identical form and roughness values no longer look the same in the data when their MSF differ.
This gives the development team a basis to trace periodic structures back to process parameters such as feed, and to assess their grinding and finishing machines against an optical criterion, not only against form and roughness.
Struggling with ripple or tool marks on precision optics? Let's look at your surfaces together.