PSV-400 Scanning Vibrometer - Technical Data
General Specifications
|
|
|
Working distance
|
> 0.4 m (shorter distances accessible by using close-up unit) |
|
Laser wavelength |
633 nm, visible beam |
|
Laser protection class |
Class II He-Ne laser, < 1 mW, eye-safe |
|
Sample size |
Several mm² up to m² range |
|
Scan grid |
Multiple grid densities and coordinate systems (polar, cartesian and hexagonal) each with up to 512 x 512 points |
Configurations
|
|
|
PSV-400-B
|
Basic Scanning Vibrometer |
2 channels, 40 kHz, 10 m/s |
|
PSV-400-H4
|
High End Scanning Vibrometer |
4 channels, 80 KHz, 10 m/s |
|
PSV-400-H4-S
|
High Amplitude Scanning Vibrometer |
4 channels, 80 KHz, 20 m/s |
|
PSV-400-M2
|
Wide Bandwidth Dual Channel Scanning Vibrometer |
2 channels, 1 MHz, 10 m/s
|
|
PSV-400-M4
|
Wide Bandwidth Four Channel Scanning Vibrometer |
4 channels, 1 MHz, 10 m/s
|
|
PSV-400-M2-20 |
20 MHz Scanning Vibrometer |
2 channels, 20 MHz, 10 m/s |
PSV-400 Hardware
|
|
|
Sensor Head PSV-I-400
|
Components:
- High sensitivity vibrometer sensor model OFV-505
- High precision scan unit (scanning range ± 20° about X, Y)
Angular resolution < 0.002°, angular stability < 0.01° /hr
- Color video camera with Auto Focus and 72x Zoom
(4x digital, 18x optical)
Features:
- Scan speed up to 50 points/s
- Individual focusing of each scan point utilizing remote focus control with memory position function
- Mountable rangefinder for acquisition of test sample geometry (optional)
- Working distance > 0.4 m (standard)
- Weight 7.5 kg
- Dimensions (L x H x W) 365 mm x 160 mm x 190 mm
|
|
Vibrometer Controller OFV-5000
|
- Velocity ranges: 2/10/50/100/1000 [mm/s/V]
(PSV-400-B: 10/100/1000 [mm/s/V]; (PSV-400-M2-20: 5/25/125/1000 [mm/s/V]; further ranges dependent on the decoder configuration)
- Bandwidth: 1.5 MHz (PSV-400-M2-20: 20 MHz)
- Four analog low pass filters with limit frequency 5 kHz,
20 kHz, 100 kHz and 1.5 MHz resp.
- RS 232 interface for remote control by the Data Management System
|
|
Junction Box PSV-E-401 |
Interface between PSV-I-400 Sensor Head, OFV-5000 Vibrometer Controller and the Data Management System
- Input for up to 4 analog signals, triggers and gate available on BNC connectors, ICP-compatible
- Output for signal generator available on BNC connectors
|
|
Junction Box Extension PSV-A-408 (option for PSV-400-H4 only) |
Additional 4 acquistion channels with corresponding BNC connectors in a separate 19" cabinet |
Data Management System PSV-W-400 |
State-of-the-art rack-mountable industrial PC equipped with:
- DVD-Recorder
- 21“ LCD Display
- 100 MB Ethernet network connection
- Data acquisition:
PSV-400-B 2 channels, 40 kHz bandwidth PSV-400-H4 4 channels, 80 kHz bandwidth PSV-400-H4-S 4 channels, 80 kHz bandwidth PSV-400-M2 2 channels, 1 MHz bandwidth PSV-400-M4 4 channels, 1 MHz bandwidth PSV-400-M2-20 2 channels, 20 MHz bandwidth
- Signal generator
- Operating system Windows® XP
(German, English and Japanese version available) |
|
Systems cabinet, rollable (optional) |
Houses PC Workstation, Vibrometer Controller, Junction Box and Data Management System
|
|
Motorized pan/tilt head (optional) |
Maximum panning angle (horizontal): ± 90°, Maximum tilt angle (vertical): ± 84°
|
| |
|
 |
PSV-400 Software Features
|
|
|
2D Alignment
|
Simple and interactive procedure to align the coordinates of the video image to the coordinates of the scanners |
|
|
Two alternatives:
- Manual, interactive definition in the live video image by APS Pro-fessional (Advanced Point Selection), allows multiple grid densities and coordinate systems (polar, cartesian and hexagonal) each with
up to 512 x 512 points combined in one scan
- Data import from CAD- and FEM-systems via Universal File Format (UFF) or ASCII or binary from MEscope (optional)
|
|
Focus control
|
- Focus Scan and Focus Memory used to determine and save the optimum focus position of each respective scan point
|
|
|
- Simultaneous data acquisition from up to 4 channels (vibrometer signal, 3 reference signals)
- Acquisition modes: FFT; zoom-FFT (optional available except for B);
fast scan (optional for B); multi frame (optional, only for H); time mode (optional)
- Digital filtering and averaging available
- Trigger options: external, analog, pre and post trigger
|
|
Data quality
|
Continuous assessment of the S/N ratio in order to improve data quality by Signal Enhancement (increased number of samples used for averaging) and Speckle Tracking |
|
Target data
|
- Velocity is measured; displacement (calculated by integration of velocity) and acceleration (calculated by differentiation) can also be displayed
- Data are saved in form of either spectra or time signal (optional for scan data)
- Calculation of transfer functions between primary and reference signals: FRF, H1, H2, Coherence, Autopower, Crosspower
|
|
Data presentation
|
Spectral presentation:
- Spectrum averaged over all scan points
- Spectra of individual points
Display of video image overlaid with measured data and various presentation modes of deflection shapes:
- 2D: color map presentation of vibration data
- 3D: 3-dimensional presentation of vibration data
- Isolines: equivalent values are interconnected by colored isolines
- Scan point: Each scan point is depicted as a square symbol colored according to the measured value
Profile representation of section cuts across the test sample which are created interactively |
|
Data export |
- Windows® Automation Interface: Polytec FileAccess
(enables data access utilizing Visual Basic or C++)
- Export of geometry data, spectra, time signals and deflection shapes as UFF- and ASCII-file (Excel format), optional
- Export of animated 2D- and 3D-models and profiles as AVI-file
|
|
Signal generation |
The internal signal generator is used to create specific excitation signals |
| |
|
 |
|
 |
|
|